-40%

CTCSS Frequency Meter Tester Transmit receiver RF Signal Generator NEW FM Tester

$ 82.1

Availability: 28 in stock
  • Restocking Fee: No
  • Brand: Unbranded
  • Refund will be given as: Money Back
  • All returns accepted: Returns Accepted
  • MPN: Does Not Apply
  • Item must be returned within: 30 Days
  • Condition: New
  • Return shipping will be paid by: Seller

    Description

    Store category
    Sign Up Now !
    You may also like
    CTCSS Frequency Meter Tester Transmit receiver RF Signal Generator NEW FM Tester
    Product Description
    Description:
    Feature :
    1 transmit
    1) Frequency Measurement :10M ~ 900M , resolution :1K or 0.1K
    2) Power measurement : 0.1W ~ 64W
    3) CTCSS measurement : 50HZ ~ 260HZ , standard digital and analog CTCSS
    2. Receive
    RF signal generator frequency range: 1M - 470M, output level : -132dBm ~ -90dBm
    Tone modulation :50HZ --- 260HZ CTCSS
    Designed for U / V FM walkie-talkie debugging, measuring development.
    Signal generator can work in duplex mode, that is measured by placing the transmit does not affect the status of generator operation,
    it can be used to measure the state of the repeater forwar
    FM FM Interphone Comprehensive Tester (RF Signal Source Function, Power Meter Function, Frequency Meter Function, Subtone Measurement Function)
    I. Emission Measurement
    1. Frequency measurement 10MHz-900MHz resolution 1KHz or 0.1KHz
    2. Power measurement 0.1W~64W (the greater the power, the shorter the test time and avoid overheating)
    3. Subaudio Measurement of 50Hz-260Hz Analog Subtone and Standard Digital Subtone
    II. Receiving Measurement
    1. Radio Frequency Signal Generator 1MHz--470MHz
    2. Output level: - 132 dBm to - 90 dBm
    3. Monotone modulation: 1KHz 2KHz 3KHz optional, output modulation: 3K
    4. Subtone Output: 50Hz - 260Hz Analog Subtone and Standard Digital Subtone, Output Amplitude: 0.5K
    3. Relay Test
    It is specially designed for debugging and measuring of U/V repeater and FM walkie-talkie. The signal generator can work in duplex mode, that is, the machine under test is placed in the transmitting state without affecting the generator's work, and can be used for measuring in the transmitting state of the turntable.
    IV. Working Voltage: 8-12V DC (DC)
    V. Working Current: 200 mA
    6. No power supply, no test line, no paper instructions. See the web page for details.
    Net weight: 400 grams
    Interphone Comprehensive Survey Explanation
    Signal source mode:
    First line left frequency (0.5-470M), right output power (-90 - - 131dBm)
    The second line of left sub-audio (50.0-280.0Hz arbitrary analog sub-tone and 105 sets of digital sub-tone) right modulated tone (1-3K) right lower corner shows input power.
    Number key: Direct input for cursor pointing item
    Up and down keys: step by step adjust the cursor pointing to the item value
    F1 key: cursor pointing to move (long press switch to frequency meter mode)
    F2 key: backspace key
    F3 key: Function key cursor pointing to output power, sub-tone, modulation tone is cyclic switch function, for example: when cursor pointing to power output, the key function is cyclic switch signal output.
    F4 key: unused
    Analog sub-tone settings: direct input of 4 digits of sub-audio points, not enough 4 digits before the "0" case 88.5 Hz input of 0, 8, 8, 5
    Now if you use the up and down keys to adjust, it will be 0.1Hz step by step. If you need to input 0, 0, 0, 0 with the up and down keys to adjust with the standard 50 sets of sub-tones, you will adjust from the first standard sub-tone 67Hz.
    Digital sub-tone settings: Input 3-digit digital sub-tone and press F3 023 to input 0, 2, 3 and then press F3 to set up successfully. Press F2 to switch between I and N of digital sub-tone, and adjust the up and down keys to add and subtract in 105 groups of digital sub-tones.
    The value input 0 of the modulation and subsonic is equivalent to the closure.
    Step Frequency Settings: When the cursor points to the frequency, the step frequency is saved according to the frequency currently displayed in F3.
    Cymometer mode:
    First line left frequency, right measurement mode AUTO / MANUA (for simultaneous measurement of intercom or repeater transmissions, select AUTO mode)
    Second line left sub-audio right frequency resolution (1K/0.1K) (in order to test the frequency drift of radio or repeater transmission frequency, 0.1k can be selected to be more accurate) lower right corner display input power
    Number key: unused
    Up and down keys: not used
    F1 Key: Long Press Switches to Signal Source Mode
    F2 key: unused
    F3 key: Resolution switching of frequency meter 1K/0.1K
    F4 key: When measuring mode switching AUTO / MANUA AUTO, the stable frequency is detected, then the subsonic is automatically locked and detected, and the result is displayed until the signal disappears. After the signal disappears, the new stable frequency is detected again. (You can test the standard and non-standard analog sub-tones emitted by the radio by yourself. If the radio emits digital sub-tones, only the standard digital sub-tones can be detected, but the non-standard digital sub-tones can not be detected.)
    In MANUA, the update frequency is detected in real time for the conventional frequency meter.
    Note: Whenever there is a power input, the lower right corner shows the input power.
    Shape size: 160*160*65mm (including protruding part)
    According to the calibration of HP8921A radio comprehensive tester:
    1. Frequency accuracy within 50 Hz
    2. The output signal intensity of v-segment is equivalent to HP8921A.
    3. The output signal intensity of U segment is 4 DBM larger than that of HP8921A (when weak signal is output, for example, when the instrument shows - 125 dbm, the actual value is - 121 dbm), and when strong signal is output, it is the same as that of HP8921A (for example, when - 90 DBM or so).
    4. The audio modulation degree of the signal output is 3K.
    5. Subtone Modulation in Signal Output is 0.5K
    6. The minimum power input required for the function of the frequency meter is 1MW (external antenna, 1W intercom can be measured at short range)
    7. The power meter is equal to HP8921A when it is over 0.2w. When it is less than 0.2w, the display value is about 20% larger than the actual value (estimated to be the reason for rounding 4 to 5 rounds).
    8. When the test power exceeds 5w, please shorten the test time properly to avoid long-term high-power test, because the heat sink inside is limited and overheating is avoided. If it really needs long-term high-power test, please increase the radiator area and add fans to compel heat dissipation.
    9. If no signal output is found in the small synthetic survey, it can be input in the mode of signal source: 001.0000 to see whether 498M and 499M frequencies have signals with the spectrum.
    Package Including:1xFM walkie-talkie Power Frequency Meter Tester
    Payment
    Delivery details
    Terms of sales
    About us
    Contact us
    Payment
    We accept paypal and all major credit cards through PayPal only.
    To avoid unpaid item dispute,all payment must be received within 7days from the end aiction.
    Note:Please list your special requests (color, packages, etc.) in the EBAY/PAYPAL NOTES SECTION when you make payment.
    Delivery details
    >tems will be shipped within 1~2 business day after payment received.
    > Items are shipped from China using Airmail, delivery time depends on destination and other factors,reach most of the countries within 10 to 35 business days.
    > if you choose the standard shipping method or SpeedPAK the item will get to you with in 20 days.
    Country
    Shipping Way
    Shipping Time
    Tracking Number
    United States
    SpeedPAK
    7-18
    Yes
    Russian
    Post by Air Mail
    15-35
    Yes
    Other Country
    Post by Air Mail
    15-45
    No
    Brazil / Africa
    Post by Air Mail
    35-65
    No
    Terms of sales
    To keep our quality service high, please make sure you read our returns and payment policies carefully before bidding or buying. We do try our best to help customers with any questions that they may have.
    We stand behind our products 100% and carefully inspected by us.
    Customers may request for an exchange or refund less shipping & handng within 30 days of receipt.
    Return of non-defective or wrongly purchased items will be subject to a 20% restocking fee.
    Product must be returned in is original packaging.
    Buyers are responsible for paying the return shipping & handing charges for any replacement or refund request.
    About us
    1.
    Factory Direct
    Have peace of mind knowing that your order will arrive brand new in its original factory sealed packaging. That means that you'll have the full force of the manufacture warranty to protect your purchase.
    2.
    Reasonable Price with Best Quality
    Our well-designed QC process and professional technology guarantees the good quality.
    3.
    Big range with many different models for selection
    To meet different requirements for different clients, we have over 300 models with multi functions for your selection.
    4.
    Commitment
    We are committed to making sure that you leave this transaction satisfied.That means having access to real people that get your questions and concerns answered quickly.Give us a shot and we will make sure that you will look to us again!
    Contact us
    If If you have any questions or concerns please reach us during our business hours of Monday-Friday 9am-6:30pm in working day through ebay messages.Thank you!
    Feedback